DABERS ANPR

Electrical wiring: pre-2018 MOT

This is pre-2018 MOT wording. The defect categories changed on 20 May 2018.

Now called Electrical wiring.

10 pre-2018 fail items.

Old wordingInspection manualNow
Electrical wiring insecureElectrical wiring insecure or inadequately supported so that it is likely to become damagedElectrical wiring insecure (minor)
Electrical wiring inadequately supportedElectrical wiring insecure or inadequately supported so that it is likely to become damagedElectrical wiring insecure (minor)
Electrical wiring damaged, likely to cause a shortElectrical wiring damaged or deteriorated to the extent that it is likely to cause a short circuit or become detachedElectrical wiring insulation so damaged or deteriorated it is likely to cause a short-circuit (major)
Electrical wiring damaged, likely to become detachedElectrical wiring damaged or deteriorated to the extent that it is likely to cause a short circuit or become detachedElectrical wiring insulation so damaged or deteriorated it is likely to cause a short-circuit (major)
Electrical wiring deteriorated, likely to cause a shortElectrical wiring damaged or deteriorated to the extent that it is likely to cause a short circuit or become detachedElectrical wiring insulation so damaged or deteriorated it is likely to cause a short-circuit (major)
Electrical wiring deteriorated and bare wires exposedElectrical wiring insulation damaged or deteriorated to the extent that bare wiring or connectors are exposed.Electrical wiring insulation slightly damaged or deteriorated (minor)
Electrical wiring damaged and bare connector exposedElectrical wiring insulation damaged or deteriorated to the extent that bare wiring or connectors are exposed.Electrical wiring insulation slightly damaged or deteriorated (minor)
Electrical wiring deteriorated and bare connector exposedElectrical wiring insulation damaged or deteriorated to the extent that bare wiring or connectors are exposed.Electrical wiring insulation slightly damaged or deteriorated (minor)
Electrical wiring deteriorated, likely to become detachedElectrical wiring damaged or deteriorated to the extent that it is likely to cause a short circuit or become detachedElectrical wiring insulation so damaged or deteriorated it is likely to cause a short-circuit (major)
Electrical wiring damaged and bare wires exposedElectrical wiring insulation damaged or deteriorated to the extent that bare wiring or connectors are exposed.Electrical wiring insulation slightly damaged or deteriorated (minor)

Current names are the closest match by wording and part. The DVSA publishes no official old-to-new table.

Other pre-2018 parts in Lamps, Reflectors and Electrical Equipment

Dabers ANPR shows the full MOT history, defects included, for the car in any photo. How it works

Add to Chrome

Contains public sector information from the DVSA licensed under the Open Government Licence v3.0.