DABERS ANPR

MOT defects: Operation (Air and vacuum systems)

Brakes

4 defects: 1 dangerous, 2 major, 1 minor. 2 can be given as an advisory instead.

Certificate wordingSeverityAs an advisoryInspection manual
Operation has insufficient reserve pressure/vacuum to provide assistance for at least two more brake applications after the warning device has operated (or gauge shows an unsafe reading)dangerousNoneInsufficient pressure/vacuum assistance for less than two brake applications after warning device has operated (or gauge shows an unsafe reading)
Operation has insufficient reserve pressure/vacuum to provide assistance for at least four more brake applications after the warning device has operated (or gauge shows an unsafe reading)majorpressure/vacuum assistance close to minimum requirementInsufficient pressure/vacuum assistance for less than four brake applications after warning device has operated (or gauge shows an unsafe reading)
Operation stored air pressure or vacuum depletes when ancillary equipment is operatedmajorNoneRepeated operation of any ancillary air or vacuum system completely depletes the stored air or vacuum for the braking system.
Operation has excessive oil dischargeminorslight discharge of oilExcessive oil discharge from a compressor or brake valve

Pre-2018 names for this part

Other parts in Brakes

All Brakes defects

Dabers ANPR shows the full MOT history, defects included, for the car in any photo. How it works

Add to Chrome

Contains public sector information from the DVSA licensed under the Open Government Licence v3.0.